''BONDETECTOR DAMI-C09'' Composite Materials Bond Tester
Transducers characteristics
The transducers are intended for detection of such defects as disbonds, unbonds,
delaminations in bonded composite materials, honeycomb constructions based on metal, carbon-fiber reinforced
plastic, glass-reinforced plastic, in different combinations and by single-sided testing.
Height (mm) 75 Diameter (mm) 35 Weight, (g), not more than 200 Length of the connecting cable (m) 1,50 Zone of the tip’s contact with tested surface (mm2) 1 Contact type dry, point Built-in position sensor no Defect alarm indicator light yes The defects are effectively detected on the specimens Specimen2, Specimen3, Specimen5, Specimen6, Specimen7, Specimen8, Specimen10, The eddy current transducer VTP–1C-02 is intended to detect corrosion on the backside of metal sheets manufactured from the non-ferromagnetic materials. Frequency range (kHz) 1,5-2,0 Maximal thickness of the tested sheet (mm) 5 The minimal detected subsurface defect: Height (mm) 75 Diameter (mm) 30 Weight (g), not more than 300 Length of the connecting cable (m) 1,50 Defect alarm indicator light yes Frequency range (MHz) 1,0-6,0 Diameter of the working area, (mm) Ø3 The signal amplitude ratio 'Air/ÎÍ-4 specimen' at the frequency of 5 MHz, (dB), not less than 12 The minimal detected groove-like defect, having the depth of, (mm) Nominal working gap, (mm) 0,2 Defect alarm indicator light yes (for DAMI-C) Operating temperature range, (°Ñ) from minus 20 to plus 50 Connector type Lemo10 socket Length, (mm) 75 Housing diameter (mm) 14 Weight (g), not more than 100 Length of the connecting cable (m) 1,50 Frequency range (MHz) 1,0-6,0 Diameter of the working area, (mm) Ø3 The signal amplitude ratio 'Air/OH-4 specimen' at the frequency of 5 MHz, (dB), not less than 12 The minimal detected groove-like defect, having depth, (mm) Nominal working gap, (mm) 0,2 Defect alarm indicator light yes (for DAMI-C) Operating temperature range, (°Ñ) from minus 20 to plus 50 Connector type Lemo10 socket Length, (mm) 75 Width, (mm) 40 Housing diameter (mm) 14 Weight (g), not more than 100 Length of the connecting cable (m) 1,50 Frequency range (MHz) 0,4-0,8 Diameter of the working area, (mm) Ø7 The signal amplitude ratio 'Air/OH-4 specimen' at the frequency of 5 MHz, (dB), not less than 12 The minimal detected groove-like defect, having the depth (mm) Nominal working gap, (mm) 0,5 Defect alarm indicator light yes (for DAMI-C) Operating temperature range, (°Ñ) from minus 20 to plus 50 Connector type Lemo10 socket Length, (mm) 66 Housing diameter (mm) 14 Weight (g), not more than 100 Length of the connecting cable (m) 1,50 Frequency range (MHz) 0,4-0,8 Diameter of the working area, (mm) Ø7 The signal amplitude ratio 'Air/OH-4 specimen' at the frequency of 5 MHz, (dB), not less than 12 Minimal detected groove-like defect, having depth, (mm) Nominal working gap, (mm) 0,5 Defect alarm indicator light yes (for DAMI-C) Operating temperature range, (°Ñ) from minus 20 to plus 50 Connector type Lemo10 socket Length, (mm) 66 Width, (mm) 40 Housing diameter (mm) 14 Weight (g), not more than 100 Length of the connecting cable (m) 1,50 Frequency range (MHz) 1,0-6,0 Diameter of the working area, (mm) Ø3 Signal amplitude ratio 'Air/OH-4 specimen' at the frequency of 5 MHz, (dB), not less than 12 Minimal detected groove-like defect, having depth (mm) Nominal working gap, (mm) 0,2 Defect alarm indicator light yes (for DAMI-C) Operating temperature range, (°Ñ) from minus 20 to plus 50 Connector type Lemo10 socket Length, (mm) 175 Housing diameter (mm) 14 Weight (g), not more than 100 Length of the connecting cable (m) 1,50 Height (mm) 75 Width (mm) 30 Weight, (g), not more than 300 Length of the connecting cable (m) 1,50 Zone of the tip’s contact with tested surface (mm2) 1 Contact type dry, point Built-in position sensor yes Defect alarm light indicator light yes The defects are effectively detected on the specimens
Impact frequency, (Hz) 2-5±1 "Defect/Defect-free" impact length ratio on the testing specimen TS-1 (defect 20õ20mm), not less than 3 Contact type dry, point Operating temperature range, (°Ñ) from minus 10 to plus 50 Defect alarm indicator light yes Diameter of the working area, (mm) Ø12±0,1 Dimensions, (mm), not more than Ø35õ75 Weight (g), not more than 200 Length of the connecting cable (m) 1,50 Defects are effectively detected on the specimens Specimen2, Specimen3, Specimen6, Specimen7, Specimen8, Specimen10, Specimen12,
|